Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial. Armoured LSZH mains cable to British Standard BS6724 & IEC60502 suitable for power networks.
Conductor identification:
Two Core - Brown, Blue
Three Core - Brown, Black & Grey (Optional: Brown, Blue & Green/Yellow)
Four Core - Brown, Black, Grey & Blue (Optional: Brown, Black, Grey & Green/Yellow)
Five Core - Numbered Cores (Optional: Brown, Black, Grey, Blue + Green/Yellow)
Six Core and Above - Numbered Cores (optional numbered + Green and Yellow)
Conductor stranding:
Class 2 stranded copper:
2 circular or circular compacted conductors
2* shaped or circular conductors or circular compacted conductors.
2S shaped conductors
(Dimensions and weights based on circular)
Conductors: Plain annealed stranded copper
Insulation: XLPE (Cross linked polyethylene)
Bedding: LSZH (Low smoke zero halogen)
Armour/Protection: SWA (Galvanised single wire armour)
Sheath/Jacket: LSZH (Low smoke zero halogen)
Colour: Black
Voltage:600/1000v
Operating temperature: Maximum 90°C. Minimum bending 0°C
Minimum bending radius:
1.5 sq.mm – 16 sq.mm –6 x overall diameter (circular cond.)
25 sq.mm and above – 8 x overall diameter (shaped cond.)
Standards:
BS6724: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V, having low emission of smoke and corrosive gases when affected by fire BSEN50267-1Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Apparatus BSEN50267-2-1:Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Procedures. Determination of the amount of halogen acid gas BSEN50266-1Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables IEC60502: Power cables with extruded insulation and their accessories for rated voltages from 1kV to 30kV BSEN/IEC60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1: test for vertical flame propagation for a single insulated wire or cable Section 2: procedure for 1kW pre-mixed flame BSEN61034-2:2005 Measurement of smoke density of cables burned under defined conditions. Test procedure and requirements
Flame Propagation Test to BS EN 60332-1-2:2004 for single cable and BS EN 60332-3-24:2009 (Cat C) for multiple cables
Notes: If you are considering installing in high UV exposure and/or high/low ambient temperatures i.e. desert/arctic conditions then special sheathing may be required