Application: Offshore Application, Backbone cabling, General purpose armored Outdoor, Long Distance OSP, Outdoor Plant Duct Installation, Rugged environments. The cable contains color-coded optical fibers contained in color-coded loose tubes. These tubes are filled with a thixotropic gel to prevent the ingress of water,mica tape added over each tube for heat protection. These tubes are SZ stranded with 2 fillers around a metal central strength ember. Fiber-glass strength yarns reinforce the cable core beneath an inner HFFR jacket. A layer of 0.3 mm galvanised steel wires is stranded around the inner jacket to serve as a braid. An outer MUD resistant UV XLHF with UV stabilized and attack proof against aliphatic hydrocarbons jacket completes the cable structure.
Sheath: XL-HFFR
Buffer Material: PBT
Tube Diameter: 2.5 mm nom.
Color code: Per TIA/EIA 598-C
Central Strength Member: Steel
Cabling: SZ
Strength Elements: E-Glass Yarns
Overall Braid Material: Steel wire
Braid Coverage: 87%nom.
Inner Jacket Material: LSZH
Inner Jacket Thickness: 1.4 mm
Inner Jacket 1 Thickness: 1.2 mm min.
Total Number of Tubes: 2
Rip-Cord: Yes
Outer Jacket Thickness: 1.7 mm nom. (1.5 mm min)
Outer Jacket Color: Black
Breaking Strength: 6600 N
Tensile Strength Short Term: 3300 N max.
Long Term: 2000 N max.
Impact Resistance: 4.4 N•m, 3 cycles
Max. Crush Resistance: 400 N/cm
Min. Bend Radius: For installation and operation: 20xD mm
Repeated Bending: 25 cycles
Temperature guide: Max. Operating Temperature: +80 °C
Min. Operating Temperature: -40 °C
Max. Installation Temperature: +55 °C
Min. Installation Temperature: -20 °C
Max. Storage Temperature: +80 °C
Min. Storage Temperature: -40 °C
Resistance: UV and Mud
Standards: Applicable Standards: DNV TYPE DA Armored FiberOptic Cable, IEC 60794, ISO/IEC 11801, TIA/EIA-568, RoHS-2 2011/65/EU
Flamability Rating: IEC 60331-25, IEC 60332-3 , IEC 60754-1/2, IEC 60754, IEC 61034
Installation: Guidelines as per IEC 60794-1-1 Annex A

Whilst Selectus LLP endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Selectus LLP is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.   

Technical Information

Specification

Batt Part No. Core Size Colour/Reference Quote
93526 4 9/125 Black
93527 8 9/125 Black
93528 12 9/125 Black
93519 4 62.5/125 Black
93530 4 50/125 Black
93531 8 50/125 Black
93532 12 50/125 Black