Уважаемые покупатели, актуальность цен и наличие товара уточняйте у менеджера.

RFOU (i) Instrumentation Cable 150/250V, mud resis

RFOU instrumentation cable, mud resistant to NEK606 

Applications: Fixed installation for power, control and lighting. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009.

Conductors: Tinned annealed stranded copper

Twisting: two/three insulated cores shall be twistedtogether to form a pair/triple

Core identification: Pairs: Black & blue Triples: Black, blue & Brown

Insulation: Halogen free EPR (Ethylene Propylene Rubber),

Screen: ICM (individual copper mylar) and a TCWB (Tinned copper wire braid)

Sheath/Jacket: Type: SHF2 MUD, thermoset dual compound, halogen free and mud resistant

Sheath colours: Blue & Grey

Voltage: 150/250v

Operating temperature: Maximum 90°C, Cold bend -40°C / Cold impact -35°C

Max bending radius: 6 x OD 

 Ref: RFOU

Standards: IEC60092-376: electrical installation in ships, power cables,
NEK606: cables for offshore installation halogen-free or mud-resistant,
IEC 60092-376:2003: Electrical installations in ships – cables for control instrumentation circuits 150/250v (300v)
IEC60332: flame retardant,
IEC61031-1.2: smoke denisty,
IEC60754-1, halogen free properties,
IEC60228: electical conductor

Applications: Mud resistant cable for control, instrumentation and telecommunications

Type Approvals: ABS & DNV,

Meets the UVresistance requirements of UL1581 or HD605 part 2.5.12

ABS

Whilst Selectus LLP endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Selectus LLP is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.  

Batt Part No. Core Size Colour/Reference Quote
67427 1 pair 0.75sqmm (Class 2) Grey
67458 1 pair 0.75sqmm (Class 2) Blue
67824 1 pair 1.5sqmm (Class 2) Grey
67825 1 pair 1.5sqmm (Class 2) Blue
67787 1 triple 0.75sqmm (Class 2) Grey
67362 1 triple 0.75sqmm Blue
67826 1 triple 1.5sqmm (Class 2) Blue
67785 2 pair 0.75sqmm (Class 2) Blue
67027 2 pair 0.75sqmm (Class 2) Grey
67031 2 pair 1.5sqmm (Class 2) Blue
67826 2 triples 0.75sqmm (Class 2) Blue
67619 4 pair 0.75sqmm (Class 2) Grey
67880 4 pair 0.75sqmm (Class 2) Blue
67816 4 pair 1.5sqmm (Class 2) Grey
67905 4 pair 1.5sqmm (Class 2) Blue
67002 4 triples 0.75sqmm Grey
67975 7 triples 1.5sqmm Blue
67935 8 pair 0.75sqmm Grey
67424 8 pair 0.75sqmm Blue
67428 8 pair 1.5sqmm Grey
67032 8 triples 0.75sqmm Grey
67439 8 triples 1.5sqmm Blue
67987 12 pair 0.75sqmm Grey
67978 12 pair 0.75sqmm Blue
67441 12 pair 1.5sqmm (Class 2) Grey
67320 12 pair 1.5sqmm (Class 2) Blue
67033 12 triples 0.75sqmm Grey
67469 16 pair 0.75sqmm Blue
67988 16 pair 0.75sqmm Grey
67221 16 pair 1.5sqmm Grey
67947 16 pair 1.5sqmm (Class 2) Blue
67034 16 triples 0.75sqmm Grey
67451 24 pair 0.75sqmm Blue
67862 24 pair 0.75sqmm Grey
67950 24 pair 1.5sqmm Blue
67453 24 pair 1.5sqmm Grey
68426 8 pairs 1.5sqmm Blue
68502 1 triple 1.5 Grey
67826 1 triple 1.5 Blue
67787 1 triple 0.75 Grey
67826 1 triple 1.5 Grey
67002 4 triples 0.75sqmm Grey
67827 2 1.5
68513