BFOU (i) Instrumentation Cable, 250V mud resistant

BFOU (i) Instrumentation Cable, 250V mud resistant от компании Selectus - фото 1
Цену уточняйте
В наличии

Доставка

 Самовывоз в г. Атырау
Бесплатно
 DPD
2 000 - 7 000 тг
Подробнее о доставке

Оплата

 Оплата на карту «Kaspi Bank»
 Оплата по реквизитам на расчетный счет

Описание

Уважаемые покупатели, актуальность цен и наличие товара уточняйте у менеджера.

BFOU (i) Instrumentation Cable, 250V mud resistant

BFOU instrumentation cable, mud resistant to NEK606 

Applications: Fixed installation for power, control and lighting where requirement for fire resistance exists. For installation in areas exposed to MUD and drilling/cleaning fluids. Meets the MUD resistance requirement in NEK TS 606:2009.

Conductors: Tinned annealed stranded copper 

Twisting: two/three insulated cores shall be twistedtogether to form a pair/triple

Core identification: Pairs: Black & blue Triples: Black, blue & Brown 

Insulation: MGT (Mica glass tape), halogen free EPR (Ethylene Propylene Rubber),

Screen: ICM (individual copper mylar) and a TCWB (Tinned copper wire braid)

Sheath/Jacket: Type: SHF2 MUD, thermoset dual compound, halogen free and mud resistant

Sheath colours: Blue & Grey

Voltage: 150/250v

Operating temperature: Maximum 90°C, Cold bend -40°C / Cold impact -35°C

Max bending radius: 6 x OD 

 Ref: BFOU

Standards: NEK606: cables for offshore installation halogen-free or mud-resistant,
IEC 60092-376:2003: Electrical installations in ships – cables for control instrumentation circuits 150/250v (300v)
IEC60331: fire resistant,
IEC60332: flame retardant,
IEC61034-2 smoke denisty,
IEC60754-1, halogen free properties,
IEC60228: electical conductor

Type Approvals: ABS & DNV

Meets the UVresistance requirements of UL1581 or HD605 part 2.5.12

DNV

Whilst Selectus LLP endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Selectus LLP is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.  

Batt Part No. Core Size Colour/Reference Quote
67783 1 pair 0.75sqmm (Class 2) Blue
67789 1 pair 0.75sqmm (Class 2) Grey
67658 1 pair 1.5sqmm (Class 2) Blue
67284 1 pair 1.5sqmm (Class 2) Grey
67829 1 triple 0.75sqmm (Class 2) Blue
67753 1 triple 0.75sqmm (Class 2) Grey
67831 1 triple 1.5sqmm (Class 2) Blue
67830 1 triple 1.5sqmm (Class 2) Grey
67832 2 pair 0.75sqmm (Class 2) Blue
67754 2 pair 0.75sqmm (Class 2) Grey
67808 2 pair 1.5sqmm (Class 2) Blue
67802 2 pair 1.5sqmm (Class 2) Grey
67902 2 triple 0.75sqmm Grey
67212 2 triple 1.5sqmm Blue
67047 4 pair 0.75sqmmm (Class 2) Blue
67473 4 pair 0.75sqmm (Class 2) Grey
67790 4 pair 1.5sqmm (Class 2) Grey
67004 4 triple 0.75sqmm Grey
67000 4 triple 1.5sqmm Grey
67714 4 triple 1.5sqmm Blue
67924 8 pair 0.75sqmm Blue
67806 8 pair 0.75sqmm (Class 2) Grey
67792 8 pair 1.5sqmm (Class 2) Grey
67791 8 pair 1.5sqmm Blue
67832 8 triple 0.75sqmm (Class 2) Blue
67843 8 triple 0.75sqmm Black
67878 8 triple 1.5sqmm Grey
67475 8 triple 1.5sqmm Blue
67889 12 pair 0.75sqmm (Class 2) Grey
67794 12 pair 1.5sqmm Blue
67793 12 pair 1.5sqmm Grey
67850 12 triple 0.75sqmm Grey
67842 16 pair 0.75sqmm Grey
67795 16 pair 1.5sqmm Blue
67036 16 pair 1.5sqmm (Class 2) Grey
67805 24 pair 0.75sqmm Grey
67849 24 pair 1.5sqmm Grey
68464 4 1.5
68446 24 1.5
67832 2 0.75
68466 12 1.5
68418 Grey