RFOU Power Cable Fire Retardant 600/1000V NEK606

RFOU Power Cable Fire Retardant 600/1000V NEK606 от компании Selectus - фото 1
Цену уточняйте
В наличии

Доставка

 Самовывоз в г. Атырау
Бесплатно
 DPD
2 000 - 7 000 тг
Подробнее о доставке

Оплата

 Оплата на карту «Kaspi Bank»
 Оплата по реквизитам на расчетный счет

Описание

Уважаемые покупатели, актуальность цен и наличие товара уточняйте у менеджера.

RFOU Power Cable Fire Retardant 600/1000V NEK606

RFOU power cable, mud resistant to NEK606 

Applications: Fixed installation for power, control and lighting. For installation in areas exposedto MUD and drilling/cleaning fluids. Meets the MUD resistance requirement inNEK TS 606:2009.

Conductors: Tinned annealed stranded copper

Core identification: Single core: off-white (Grey) 2 core: off-white (Grey) & black, 3 core: off-white (Grey), black & red, 4 core: off-white (Grey), black, red & blue.

Including green / yellow core options. 

Insulation: Halogen free EPR (Ethylene Propylene Rubber),

Screen: TCWB (Tinned copper wire braid)

Sheath/Jacket: Type: SHF2 MUD, thermoset dual compound, halogen free and mud resistant

Sheath colours: Black 

Voltage: 600/1000v

Operating temperature: Maximum 90°C, Cold bend -40°C / Cold impact -35°C

Min operating radius: 6 x OD 

 Ref: RFOU


Standards: IEC60092-353: electrical installation in ships, power cables,
NEK606: cables for offshore installation halogen-free or mud-resistant,
IEC60092.375 shipboard telecommunications cable,
IEC60332: flame retardant,
IEC61031-1.2: smoke denisty,
IEC60754-1, halogen free properties,
IEC60228: electical conductor

Applications: Mud resistant cable for control, lighting and power systems

Type Approvals: ABS, DNV & Lloyd’s Register of Shipping,

Meets the UVresistance requirements of UL1581 or HD605 part 2.5.12

ABS

DNV

Lloyds

Whilst Selectus LLP endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Selectus LLP is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.  

Batt Part No. Core Size Colour/Reference Quote
67761 1 2.5sqmm (Class 2) Black
67841 1 6.0sqmm (Class 2) Black
67835 1 16sqmm (Class 2) Black
67762 1 25sqmm (Class 2) Black
67938 1 35sqmm Black
67763 1 50sqmm (Class 2) Black
67764 1 70sqmm (Class 2) Black
67765 1 95sqmm (Class 2) Black
67800 1 120sqmm (Class 2) Black
67766 1 150sqmm (Class 2) Black
67005 1 185sqmm (Class 2) Black
67277 1 240sqmm (Class 2) Black
67283 1 300sqmm Black
67918 1 500sqmm Black
67914 2 1.5sqmm (Class 2) Black
67202 2 2.5sqmm (Class 2) Black
67204 2 4.0sqmm (Class 2) Black
67411 2 6.0sqmm (Class 2) Black
67024 2 10sqmm Black
67867 2 16sqmm (Class 2) Black
67080 3 1.5sqmm (Class 2) Black
67092 3 2.5sqmm (Class 2) Black
67101 3 4.0sqmm (Class 2) Black
67107 3 6.0sqmm (Class 2) Black
67117 3 10sqmm (Class 2) Black
67811 3 16sqmm (Class 2) Black
67821 3 25sqmm Black
67817 3 35sqmm (Class 2) Black
67818 3 50sqmm (Class 2) Black
67814 3 70sqmm (Class 2) Black
67756 3 95sqmm (Class 2) Black
67847 3 120sqmm Black
67028 3 150sqmm Black
67011 3 185sqmm (Class 2) Black
68322 3 240sqmm Black
67124 4 1.5sqmm (Class 2) Black
67129 4 2.5sqmm (Class 2) Black
67131 4 4.0sqmm (Class 2) Black
67151 4 6.0sqmm (Class 2) Black
67822 4 10sqmm (Class 2) Black
67823 4 16sqmm (Class 2) Black
67897 4 25sqmm Black
67915 4 35sqmm (Class 2)
67534 4 50sqmm (Class 2) Black
67035 4 70sqmm Black
67899 4 95sqmm Black
67029 4 120sqmm Black
67153 7 1.5sqmm (Class 2) Black
67901 7 2.5sqmm Black
67936 12 1.5sqmm Black
67758 19 1.5sqmm Black
67989 37 1.5sqmm Black