Fire Resistant Power Cable BS6387

Fire Resistant Power Cable BS6387 от компании Selectus - фото 1
Цену уточняйте
В наличии

Доставка

 Cамовывоз в г. АтырауБесплатно
 DPD2 000 - 7 000 тг
Подробнее о доставке

Оплата

 Оплата на карту «Kaspi Bank»
 Оплата по реквизитам на расчетный счет

Описание

Уважаемые покупатели, актуальность цен и наличие товара уточняйте у менеджера.

Fire Resistant Power Cable BS6387

Fire performance power cable to BS6837 suitable as fire alarm cable and emergency lighting cable

Conductor: Plain annealed stranded copper to BSEN60228 (class 2) 

Fire barrier: MGT (Mica glass tape)

Insulation: XLPE (Cross linked polyethylene)

Core identification: 2 core:Brown & blue, 3 core: Brown, black & grey, 4 core: Brown, grey, blue & black, Multicore: White cores with black numerals

Bedding: LSZH (Low smoke zero halogen)

Armour/Protection: SWA (Single wire armour)

Sheath/Jacket: LSZH (Low smoke zero halogen)

Colour: Black

Voltage: 600/1000v

Operating temperature: Maximum 90°C, minimum bending: -0°C, minimum operating: -10°C

Standards: BS6387, Categories C, W & Z, Specification for performance requirements for cables required to maintain circuit integrity under fire conditions
IEC60331: Tests for electric cables under fire conditions - circuit integrity 
BS EN 61034:2005: Measurement of smoke density of cables burned under defined conditions. Test procedure and requirements
BS6724: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000V and 1900/3300V, having low emission of smoke and corrosive gases when affected by fire
BS7846: Electric cables. 600/1000 V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire
BS EN 50266:2001: Common test methods for cables under fire conditions. Test for vertical flame spread of vertically-mounted bunched wires or cables

Fire Resistance BS6387 Categories C, W & Z:
IEC60331: 750 deg C for 3 hours
Flame Propagation BS EN 50266 parts 1 and 3, IEC 60332-3, BS EN 60332:2004
Smoke Emission IEC 61034, BS EN 61034:2005
Corrosive Acid Gas BS EN 50267-2-1:1999, IEC 60754-1

Fire resistant to IEC 60331 1-2 

Applications: Fire performance cables maintain circuit integrity in a fire and so are suitable for fire detection, alarm and emergency lighting systems

Minimum Bending Radius: 6 x Overall Diameter for Circular Conductors. 8 x Overall Diameter for Shaped Conductors

Whilst Selectus LLP endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Selectus LLP is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.  

Technical Information

Batt Part No. Core Size Colour/Reference Quote
57183 2 1.5sqmm (Class 2) Black
57184 2 2.5sqmm (Class 2) Black
57185 2 4.0sqmm (Class 2) Black
57186 2 6.0sqmm (Class 2) Black
57187 2 10sqmm (Class 2) Black
57188 2 16sqmm (Class 2) Black
57189 2 25sqmm (Class 2) Black
57190 2 35sqmm (Class 2) Black
57191 2 50sqmm (Class 2) Black
57192 2 70sqmm (Class 2) Black
57193 2 95sqmm (Class 2) Black
57194 2 120sqmm (Class 2) Black
57195 2 150sqmm (Class 2) Black
57196 2 185sqmm (Class 2) Black
57197 2 240sqmm (Class 2) Black
57198 2 300sqmm (Class 2) Black
57199 2 400sqmm (Class 2) Black
57212 3 1.5sqmm (Class 2) Black
57213 3 2.5sqmm (Class 2) Black
57214 3 4.0sqmm (Class 2) Black
57215 3 6.0sqmm (Class 2) Black
57216 3 10sqmm (Class 2) Black
57217 3 16sqmm (Class 2) Black
57218 3 25sqmm (Class 2) Black
57219 3 35sqmm (Class 2) Black
57220 3 50sqmm (Class 2) Black
57221 3 70sqmm (Class 2) Black
57222 3 95sqmm (Class 2) Black
57223 3 120sqmm (Class 2) Black
57224 3 150sqmm (Class 2) Black
57225 3 185sqmm (Class 2) Black
57226 3 240sqmm (Class 2) Black
57227 3 300sqmm (Class 2) Black
57228 3 400sqmm (Class 2) Black
57200 4 1.5sqmm (Class 2) Black
57201 4 2.5sqmm (Class 2) Black
57202 4 4.0sqmm (Class 2) Black
57203 4 6.0sqmm (Class 2) Black
57204 4 10sqmm (Class 2) Black
57205 4 16sqmm (Class 2) Black
57236 4 25sqmm (Class 2) Black
57230 4 35sqmm (Class 2) Black
57237 4 50sqmm (Class 2) Black
57243 4 70sqmm (Class 2) Black
57231 4 95sqmm (Class 2) Black
57232 4 120sqmm (Class 2) Black
57233 4 150sqmm (Class 2) Black
57234 4 185sqmm (Class 2) Black
57254 4 240sqmm (Class 2) Black
57235 4 300sqmm (Class 2) Black
57253 4 400sqmm (Class 2) Black
57247 5 1.5sqmm (Class 2) Black
57248 5 2.5sqmm (Class 2) Black
57130 7 1.5sqmm (Class 2) Black
57142 7 2.5sqmm (Class 2) Black
57106 12 1.5sqmm (Class 2) Black
57143 12 2.5sqmm (Class 2) Black
57145 19 1.5sqmm (Class 2) Black
57144 19 2.5sqmm (Class 2) Black
57239 27 2.5sqmm (Class 2) Black
57125 37 1.5sqmm (Class 2) Black
57060 37 2.5sqmm (Class 2) Black
57113 48 2.5sqmm Black
57247 5 1.5
57248 5 2.5
57249 5 4
57250 5 6
57331 5 10
57329 5 16
57330 5 25