(N) TMCWOEU 26/45 kV

Способы доставки
Оплата

Описание
Уважаемые покупатели, актуальность цен и наличие товара уточняйте у менеджера.
Conductor screen: Conductive rubber
EPR-Insulation: Super clean EPR Rubber
Core screen: Conductive rubber layer, easy strippable, conductive tape, spiral of tinned copper wires
Sheath: Halogen-free compound HM3 acc. to DIN VDE 0207-24, oil resistant and flame retardant
Voltage: Test voltage, 5 min AC: 87 kV, Impulse
voltage peak: 250 kV, Partial discharge at 52 kV AC: ≤ 5 pC, Max. continuous operating voltage: 31/54 kV
Temperature: Permissible ambient temperature in operation, fixed: -40°C to +80°C
Permissible ambient temperature in operation, flexing: -25°C to +80°C
Permissible conductor temperature: max. 90°C / 230000h
Standards: Fire classes: E DIN 5510:2003-09: 1 bis 4, BS 6853: 1b, NF C 32- 070: Class C1, NF F 16-101: Class D, NF F 16-101: Class Fo
In line with DIN VDE 0250, part 813
Railway network suitability: for voltage pulses according to IEC 61287-1, for sustained over voltage according to EN 50163, Appendix A, Zone C
Permissible solar radiation: ≤ 560 W/m2 continuous, ≤1120W/ m2 for max. 12h/d
Permissible relative humidity, according to EN50125-1
Annual average: > 70 % to Daily max.: > 94%, occasional 100%, Max. absolute humidity: 40 g/m3
Operation in condensation is permissible
Permissible environmental factors: - drop/sprinkle/spray water, at rainfall = 6mm/min, - salt water, all kind of snow, ice
Stability against biological active substance: according to EN 60721-3-5, Class 5B2, rodent not permissible, Stability against chemical active substance: according to EN 60721-3-5, Class 5C2, Stability against contamination fluid: according EN 60721-3-5, Class 5F3 (Parameters to EN502204-1)
Oil resistance: IRM 902/(100 + 2) °C/72 h); tensile strength + 30%; elongation at break + 40%
Fuel resistance: IRM 903/(70 + 2) °C/168 h; tensile strength + 30%; elongation at break +40%
Acid and alkaline resistance (23±2)°C /168h, tensile strength + 30%; elongation at break min. 100% Stability against swell contamination, once a year
Transformer liquid (Baysilone M50 EL: 40°C, Shell Diala:105°C)
Cooling liquid (Antifrogen N) and refrigerant 134a appendix 1
Cleanser resistance: Outdoor cleaner (impact pressure Ozone resistance: IEC 92-350, 12.10 Typ: A Test (200 + 50) ppm/ (40 + 2) °C/72 h
Permissible mechanical stress: operational tensile load 15 N/mm2, hailstone (ice) diameter = 15 mm, impact energy Assessment of halogens Test according to - DIN VDE 0815 IEC 60754-1 and EN 50267-2-1 with HCL Corrosively of combustion gas: Test according to E50267-2-2 or IEC 60754-2 with
pH > 4,3 / conductivity Toxicity: Test according to BS 6853, Performance according vehicle category 1b, Test according to EN 50305, ITC Smoke density: - Test according to EN 50268-2 or IEC 61034-2, - light transmission > 60 %
Test according to BS 6853, Performance according to vehicle category 1b
Flame resistance: Test according to IEC 60332-1, EN 50265-2-1
Flame propagation: IEC 60332-3, Cat. C, BS 6853, Vehicle category 1b, DIN EN 50266-2-4. Cat C, NF C 32-070: C1, NF F 16-101: D (DFo)
Whilst Selectus LLP endeavours to ensure the information on the website, specification sheets and all other technical information is accurate, the information is for guidance only and it is subject to change without notice or liability. Selectus LLP is not responsible for the consequences of any inadequacies, inaccuracies or other deficiencies contained therein. When selecting cable accessories, please note that the actual cable dimensions may vary due to manufacturing tolerances.